Altronix MAXIMAL3R Datový list

Procházejte online nebo si stáhněte Datový list pro Výkonové distribuční jednotky (PDU) Altronix MAXIMAL3R. Altronix MAXIMAL3R power distribution unit PDU Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 2
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Altronix new Maximal3R rack mount access power controller distributes and switches power to access control
systems and accessories. It converts a 115VAC 50/60Hz input into sixteen (16) independently controlled 12VDC
or 24VDC fuse protected outputs. Outputs are activated by an normally open (NO) or normally closed (NC)
dry trigger input from an Access Control System, Card Reader, Keypad,
Push Button, PIR, etc. This unit will route power to a variety of
access control hardware devices including: Mag Locks, Electric
Strikes, Magnetic Door Holders, etc. Outputs will operate in both
Fail-Safe and/or Fail-Secure modes. The FACP Interface enables
Emergency Egress, Alarm Monitoring, or may be used to
trigger other auxiliary devices. The fire alarm disconnect
feature is individually selectable for any or all of the outputs.
Input:
• 115VAC60Hz.,1.9amp.
• Normallyclosed[NC]ornormallyopen[NO]
dry contact inputs (switch selectable).
Outputs:
• 12VDCor24VDC@6amptotaloutputcurrent.
• Sixteen(16)fuseprotectedoutputs.
• MaximumcurrentperACM8R-Moutputis2.5amp.
• IndividuallyselectableMagLock/Strike(Fail-Safe,
Fail-Secure) solid state fuse protected outputs.
• Thermalandshortcircuitprotectionwithautoreset.
Fire Alarm Interface:
• LatchingorNon-Latchingfirealarmresetswitch
individually selectable for each output.
• RemoteresetcapabilityforlatchingFireAlarm
Interface mode.
• FireAlarmdisconnectinputoptions:
a) Normallyopen[NO]ornormallyclosed[NC]
dry contact input.
b) Polarity reversal input from FACP signaling
circuit.
Visual Indicators:
• IndividualOutputStatusLEDslocatedonthe
front panel.
Battery Backup:
• Built-inchargerforsealedleadacidorgeltype
batteries (if batteries are required install
separate enclosure).
• Maximumchargecurrent0.7amp.
• Automaticswitchovertostand-bybattery
when AC fails.
• Zerovoltagedropwhenunitswitchesovertobattery
backup (AC failure condition).
Supervision:
• ACfailsupervision(form“C”contact).
• Lowbatteryandbatterypresencesupervision
(form“C”contact).
Additional Features:
• Removableterminalblockswithlockingscrewflange.
• 3-wirelinecord.
• Illuminatedmasterpowerdisconnectcircuitbreaker
with manual reset.
Rack Dimensions:
3.25”Hx19.125”Wx8.5”D
Shipping Weight (approximate):
- Maximal3R:12.7lbs.
Maximal3R
Rack Mount Access Power Controller
Rev.DSMaximal3R-A19K
Overview
Specifications
Zobrazit stránku 0
1 2

Shrnutí obsahu

Strany 1 - Maximal3R

Altronix new Maximal3R rack mount access power controller distributes and switches power to access controlsystems and accessories. It converts a 115V

Strany 2 - 3.25”Hx19.125”Wx8.5”D

Altronix Corp. - 140 58th Street, Brooklyn, NY 11220 • 718-567-8181 • 888-258-7669 • altronix.comFRONT3.125" 8.5" .75" 19.125" 17.

Komentáře k této Příručce

Žádné komentáře