- 2 - NetWay8/NetWay16
Overview:
Altronix NetWay8/NetWay16 Midspans provide power and pass data for PoE compliant cameras/edge devices. Cameras/
edge devices may be located up to 100m (328 ft.) from the NetWay unit. A NetWayXT repeater module can be utilized to
extend the distance an additional 100m (328 ft.) for a total range of up to 200m (656 ft.). A maximum range of
600m (1968 ft.) is possible using multiple repeaters, based on camera/device port requirement. NetWay Midspans are
capable of supporting non-PoE compliant fixed and PTZ IP cameras utilizing NetWay1512 or NetWay3012 adapters.
NetWay Specifications:
NetWay8:
•Eight(8)portsofcameras/edgedevicesoverethernet(CAT5)
cable up to a distance of 100m (328 ft.) per port.
•115VAC60Hz,3amp(NetWay8).
NetWay16:
•Sixteen(16)portsofcameras/edgedevicesoverethernet(CAT5)
cable up to a distance of 100m (328 ft.) per port.
•115VAC60Hz,4.9amp(NetWay16).
Common Specifications:
Agency Listings:
•UL/CULListedforInformationTechnologyEquipment
(UL60950-1).
Power:
•Unitprovidesupto30Wmax.fullpowerperport.
Total power: NetWay8 - 150W, NetWay16 - 300W.
•IEEE802.3afandIEEE802.3atcompliant(PoEPlus).
•Shortcircuitprotection.
Functions:
•Autodetectionandprotectionoflegacy
non-PoE cameras/edge devices.
Features (cont’d):
•Illuminatedmasterpowerdisconnectcircuitbreaker
with manual reset (switch).
•IndividualportstatusLEDs.
•IEC320-3-wiregroundedlinecord(detachable).
•Unitcanberackorshelfmounted.
•1UrackmountchassisforuseinstandardEIA19”rack.
Accessories:
NetWay1512:
•15Wadapterfornon-PoEcompliantIPcameras.
NetWay3012:
•25Wadapterfornon-PoEcompliantIP
fixed or PTZ cameras.
NetWayXT:
•PoErepeatermoduleextendsrange100m(328ft.).
Installation Instructions:
NetWay is not intended to be connected to outside plant leads.
1. AttachmountingbracketstoNetWayunitforrackorwallmountinstallation(Figs. 7 or 8, pg. 10).
Affix rubber pads to NetWay for shelf installation (Fig. 9, pg. 10).
2. Securetheunitinarackorplaceunitonashelfasdesired.
Note:Thefollowingfactorsshouldbetakenintoconsiderationwheninstallingtheserackmountunits:
a.Theunitistobeinstalledinaspacewherethemaximumambienttemperaturedoesnotexceed104ºF(40ºC).
b.Takecaretoinsurethereissufficientairflowaroundtheunitandthatobstructionsdonotimpedeit.
c.Whenmountingunitsinrack,takecaretoavoidunevenloadingwhichcancauseahazardouscondition.
3. Setilluminatedmasterpowerdisconnectcircuitbreakertothe(OFF)position(Fig. 1d, pg. 3).
4. PlugthegroundedAClinecord(included)intotheIEC320connectoroftheNetWayunit
(Fig. 1e, pg. 3).Plugunitintoareliableearthgroundedsocket.Whenusingmultipleunitsthesumoftheindividual
name plate ratings should not exceed the supply circuit rating.
5. Connectstructuredcablesfromportmarked[IN]onNetWaytothecorrespondinginputsofanethernetswitchor
video server (Fig. 1b, pg. 3, Fig. 4, pg. 5).
6. Connectstructuredcablesfromportmarked[OUT]onNetWaytoPoEcompliantcamera/edge
devices (Fig. 1a, pg. 3, Fig. 4, pg. 5).
7. UponcompletionofwiringsetilluminatedmasterpowerdisconnectcircuitbreakertotheRESET(ON)
position (Fig. 1d, pg. 3).
8. PortstatusLEDsontheNetWaywillinitializewhenPoEdevicesareconnectedasfollows:
- LEDwillilluminatewhendevicesareIEEE802.3afcompliant.
- LEDwillblinkonceandilluminatewhendevicesareIEEE802.3atcompliant(PoEPlus).