Maximal3/Maximal5/Maximal7 Access Power Controllers (Fused) - 3 -
Maximal Series Overview:
Maximal Access Power/Controllers distribute and switch power to access control systems and accessories. They convert a
115VAC 60Hz input into sixteen (16) independently controlled 12VDC or 24VDC fuse protected outputs. These Fail-Safe/
Fail-Secure power outputs may be converted to dry form “C” contacts. The outputs are activated by an open collector sink
or normally open (NO) dry trigger input from an Access Control System, Keypad, Push Button, REX PIR, etc. Units will
route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders,
etc. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices.
The fire alarm disconnect feature is individually selectable for any or all of the sixteen (16) outputs. All interconnecting
equipment must be UL Listed.
Maximal Series Configuration Chart:
Altronix
Model Number
Power Supply
Board Output
Voltage Options
Fuse Protected
Non Power-Limited
Outputs
Maximum Current
Per ACM8 Output
115VAC 60Hz Input
(current draw)
Power Supply Board
Input Fuse Rating
Power Supply
Board Output
Fuse Rating
Agency Listings
and File Numbers
Maximal3
12VDC @ 5 amp
or 24VDC @ 5.4 amp
16
2.5
amp
3.5
amp
5A/
250V
------
California State Fire
Marshal Approved
UL File # BP6714
UL 294 - UL Listed for Access
Control System Units.
Maximal5
12VDC @ 9 amp 16
2.5
amp
2.6
amp
5A/
250V
15A/
32V
Maximal7
24VDC @ 9.4 amp 16
2.5
amp
4.4
amp
5A/
250V
15A/
32V
Maximal Series Features:
• Sixteen(16)independentlytriggercontrolledoutputs.Outputoptions:
a) Sixteen (16) Fail-Safe filtered and electronically regulated power outputs.
b) Sixteen (16) Fail-Secure filtered and electronically regulated power outputs.
c) Sixteen (16) form “C” relay outputs (rated @ 5 amp/28VDC or VAC).
d) Any combination of the above.
• Sixteen(16)AccessControlSystemtriggerinputs.Inputtriggeroptions:
a) Sixteen (16) normally open (NO) dry trigger inputs.
b) Sixteen (16) open collector inputs.
c) Any combination of the above.
• Sixteen(16)unswitchedfilteredandelectronicallyregulatedaux.poweroutputs(outputsarerated@2.5amp).
• RedLEDsonACM8boardindicateindividualoutputsaretriggered(relaysenergized).
• FireAlarmdisconnect(latchingornon-latching)isindividuallyselectableforanyorallofthesixteen(16)outputs.
Fire Alarm disconnect input trigger options:
a) Normally open (NO) or normally closed (NC) dry trigger input.
b) Polarity reversal input from FACP signaling circuit.
• GreenLEDonACM8boardindicatesFACPdisconnectistriggered.
• FACPoutputrelayindicatesthatFACPinputistriggered
(form “C” contact rated @ 1 amp/28VDC not evaluated by UL).
• Powersupplyinputisfactoryinstalled.ItprovidescommonpowerforbothACM8boardsandallconnected
access control devices.
• ACM8boardmainfusesarerated@10amp.Outputfusesarerated@2.5amp.
• Built-inchargerforsealedleadacidorgeltypebatteries.
- Maximum charge current is 0.7 amp for AL600ULXB and AL1012ULXB power supply boards.
- Maximum charge current is 3.6 amp for AL1024ULXB2 power supply board.
• Automaticswitchovertostand-bybatterywhenACfails.
• Zerovoltagedropwhenunitswitchesovertobatterybackup(ACfailurecondition).
• Shortcircuitandthermaloverloadprotectionwithautoreset.
• GreenACinputandredDCoutputLEDindicatorsonpowersupplyboard(s).
• ACfailsupervision(form“C”contactrated@1amp/28VDC).
• Batteryfailandbatterypresencesupervision(form“C”contactrated@1amp/28VDC).
Altronix Corp.
140 58th St. Brooklyn, NY